prim18240:Weblogic Warning : StuckThreadMaxTime exceeded

$
0
0
Solution ID: prim18240
Weblogic Warning : StuckThreadMaxTime exceeded
Status: Reviewed
Version(s): 7.0



Fact: Version 7.0
Problem: Weblogic Warning : StuckThreadMaxTime exceeded
Problem: The following warning is reported by Weblogic in myserver.log :

<Warning> <WebLogicServer> <server> <myserver> <weblogic.health.CoreHealthMonitor> <<WLS Kernel>> <> <BEA-000337> <ExecuteThread: ’14′ for queue: ‘weblogic.kernel.Default’ has been busy for “1,675″ seconds working on the request “Http Request: /primavera/web/command”, which is more than the configured time (StuckThreadMaxTime) of “600″ seconds.> 

Fix: This is a common message from BEA in Primavera 7.0.

In general, these messages are harmless unless all threads become stuck simulataneously and the server is no longer responsive to any web request. In 7.2 and higher, changes prevent a single user from accidentally taking all threads on the BEA server.