Solution ID: prim24652 |
Error importing MPX file created in Asta Power Project |
Status: Reviewed |
Version(s): 3.5.1, 4.0, 4.1, 5.0, 6.0, 6.1, 6.2, 6.2.1, 7.0 |
Problem: | Error importing MPX file created in Asta Power Project |
Problem: | ***************************************************** * EXCEPTION REPORT * ***************************************************** Date: 21-Jun-05 Executable: PM.exe Context: Detail: |
Problem: | When the MPX file is imported to Microsoft Project, the following Warning was displayed |
Fix: | Linking an activity to the same successor with the same relationship twice is not allowed by Project Management’s business rules. To resolve this issue, please examine the original project in Asta Power Project and remove any duplicated relationships. Workaround: 1. Import the project to Microsoft Project 2. When the warning “There was a problem linking these tasks. You cannot link a predecessor task twice to the same successor task” appears, click OK. Microsoft Project will automatically fix this invalid relationship 3. Save the project and close Microsoft Project The file should now import to Project Management successfully. |